Universal Hardwired-to-Wireless RF Translator Device

SKU: RE508X

No Customer Review

$90.00

Description

Universal Hardwired-to-Wireless RF Translator Device

 

The RE-508X Universal Hardwired to Wireless converter module allows you to use existing hardwired devices on your Honeywell, 2GIG, DSC, Interlogix, QolSyS or Cryptix wireless system. This product is NOT for use with life safety devices, such as Smoke, Heat, or CO detectors.

PHYSICAL
  Housing Dimensions
8.5 x 5.0 x 1.3 inches
  Weight with Battery
16.0 Ounces

  Tamper Activation
Cover Opening, Wall Removal
Mounting Screws
#4 or #6

ENVIRONMENTAL
 Operating Temperature
32 to 120 ̊F (0 to 49 ̊C)
  Storage Temperature
-4 to 86 ̊F (-20 to 30 ̊C), Long-Term
  Maximum Humidity
85% relative humidity, non-condensing

POWER
  Power Transformer
  Input
100-240VAC 50/60Hz 0.5A
  Output
12VDC 1A
Part Number
RE012-6

Battery
  Backup
24 hours minimum
  Specifications
6VDC 800mAh NiMH
  Part Number
RE030
  Trickle Charge
8mA
  Fast Charge
32mA

WIRELESS RADIO
  RF Frequency
319.5MHz, 345MHz, 433.92MHz
  Compatibility
Interlogix® (formerly GE®),2GIG®Honeywell®, DSC®, Qolsys®, Napco®
  Sensors
Up to 128

ZONES
Supported Types
Powered Zones
4-wire devices only
Non-Powered Zones
NC (Normal closed) or NO (Normal open)

Battery Backup
Powered Zones
4 hours minimum at 80mA
Non-Powered Zones
24 hours minimum

Zone End of Line Resistor
NC – No Tamper Detect
None (short)
NC – Tamper Detect
750 ohm to 15k ohm
NO – No Tamper Detect
None (open)
NO – Tamper Detect
750 ohm to 15k ohm
Zone Wire Length
1000 feet max
Zone Wire Gauge
22 AWG min

CERTIFICATIONS
ETL Listings
  RE508X
UL1023, ULC1023
RE508XC
UL1023, ULC1023, UL1610, ULC S304
Other
FCC, IC

Specifications subject to change without notice.
This product is NOT for use with life safety sensors, such as Smoke, Heat, or CO detectors.
This product is NOT for use in bank installations.

Customer reviews

Reviews
Write a review

There are no reviews yet.